| TECHNICAL SPECIFICATIONS |
| Output |
| Output Power Capacity |
300 Watts / 500 VA |
| Max Configurable Power |
300 Watts / 500 VA |
| Nominal Output Voltage |
120V |
| Output Connections |
(3) NEMA 5-15R (Battery Backup)
(3) NEMA 5-15R (Surge Protection) |
| Input |
| Nominal Input Voltage |
120V |
| Input Frequency |
50/60 Hz +/- 3 Hz (auto sensing) |
| Input Connections |
NEMA 5-15P |
| Cord Length |
6 feet (1.83 meters) |
| Input voltage range for main operations |
98 - 140V |
| Batteries & Runtime |
| Battery Type |
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof |
| Typical recharge time |
8 hour(s) |
| Replacement battery cartridge |
CURK2, RBC2 |
| RBC™ Quantity |
1 |
| Typical Backup Time at Half Load |
13.9 minutes (150 Watts) |
| Typical Backup Time at Full Load |
2.4 minutes (300 Watts) |
Runtime Chart |
Back-UPS CS |
| Communications & Management |
| Interface Port(s) |
DB-9 RS-232,USB |
| Control panel |
LED status display with On Line : On Battery : Replace Battery and Overload indicators |
Audible Alarm |
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Surge Protection and Filtering
|
| Surge energy rating |
1020 Joules |
| Filtering |
Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449 |
| Dataline protection |
RJ-11 Modem/Fax/DSL protection (two wire single line) |
|
| Maximum Height |
6.50 inches (165 mm) |
| Maximum Width |
3.60 inches (91 mm) |
| Maximum depth |
11.20 inches (284 mm) |
| Net Weight |
13.80 lbs. (6.27 kg) |
| Shipping Weight |
15.30 lbs. (6.95 kg) |
| Shipping Height |
10.35 inches (263 mm) |
| Shipping Width |
6.89 inches (175 mm) |
| Shipping Depth |
14.06 inches (357 mm) |
| Master Carton Units |
2.00 |
| Master Carton Weight |
31.50 lbs. |
| Color |
Beige |
| SCC Codes |
1073130401630 1 |
| Environmental |
| Operating Environment |
32 - 104 °F (0 - 40 °C) |
| Operating Relative Humidity |
0 - 95% |
| Operating Elevation |
0-10000 feet (0-3000 meters) |
| Storage Temperature |
5 - 113 °F (-15 - 45 °C) |
| Storage Relative Humidity |
0 - 95% |
| Storage Elevation |
0-50000 feet (0-15000 meters) |
| Audible noise at 1 meter from surface of unit |
45 dBA |
| Online Thermal Dissipation |
24.00 BTU/hr |
| Conformance |
| Regulatory Approvals |
FCC Part 15 Class B,Industry Canada,UL 1778,cUL Listed |
| Standard Warranty |
3 years repair or replace |
| Equipment protection policy |
Lifetime : $100000 |
| |