| TECHNICAL SPECIFICATIONS |
| Output |
| Output Power Capacity |
330 Watts / 550 VA |
| Max Configurable Power |
330 Watts / 550 VA |
| Nominal Output Voltage |
120V |
| Output Frequency (sync to mains) |
60 Hz |
| Waveform Type |
Stepped approximation to a sinewave |
| Output Connections |
(4) NEMA 5-15R (Battery Backup)
(4) NEMA 5-15R (Surge Protection) |
| Input |
| Nominal Input Voltage |
120V |
| Input Frequency |
50/60 Hz |
| Input Connections |
NEMA 5-15P |
| Cord Length |
6 feet (1.83 meters) |
| Input voltage range for main operations |
88 - 139V |
| Batteries & Runtime |
| Battery Type |
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof |
| Typical recharge time |
24 hour(s) |
| RBC™ Quantity |
1 |
| Typical Backup Time at Half Load |
13.5 minutes (165 Watts) |
| Typical Backup Time at Full Load |
3.3 minutes (330 Watts) |
Runtime Chart |
Back-UPS ES |
| Communications & Management |
| Control panel |
LED status display with On Line : On Battery : Replace Battery and Building Wiring Fault |
Audible Alarm |
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Surge Protection and Filtering
|
| Surge energy rating |
365 Joules |
| Filtering |
Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449 |
| Dataline protection |
RJ-11 Modem/Fax/DSL protection (two wire single line) |
|
| Maximum Height |
3.39 inches (86 mm) |
| Maximum Width |
10.90 inches (277 mm) |
| Maximum depth |
7.09 inches (180 mm) |
| Net Weight |
13.20 lbs. (6.00 kg) |
| Shipping Weight |
14.30 lbs. (6.50 kg) |
| Shipping Height |
4.69 inches (119 mm) |
| Shipping Width |
15.00 inches (381 mm) |
| Shipping Depth |
8.90 inches (226 mm) |
| Master Carton Units |
2.00 |
| Master Carton Dimensions (Length x Width x Height) |
15.8 x 10.2 x 9.5 inches (401 x 259 x 241 mm) |
| Master Carton Weight |
29.00 lbs. (13.18 kg) |
| Color |
Charcoal |
| SCC Codes |
1 073130424806 1 |
| Units per Pallet |
120.00 |
| Environmental |
| Operating Environment |
32 - 104 °F (0 - 40 °C) |
| Operating Relative Humidity |
5 - 95% |
| Operating Elevation |
0-10000 feet (0-3000 meters) |
| Storage Temperature |
5 - 113 °F (-15 - 45 °C) |
| Storage Relative Humidity |
5 - 95% |
| Storage Elevation |
0-50000 feet (0-15000 meters) |
| Audible noise at 1 meter from surface of unit |
45 dBA |
| Online Thermal Dissipation |
14.00 BTU/hr |
| Conformance |
| Regulatory Approvals |
cUL Listed,FCC Part 15 Class B,FCC Part 68,NOM,UL 1778,UL 497A,UL 497B |
| Standard Warranty |
3 years repair or replace |
| Equipment protection policy |
Lifetime : $75000 |
| |